North Anna does not assign DAC-hrs based on CAM readings.

From: [email protected] [mailto:[email protected]] On Behalf Of 
Creamer, Charles E
Sent: Monday, January 23, 2012 10:32 AM
To: [email protected]
Subject: Powernet: DAC Hour Assignment from CAMS

One of our managers completed a self assessment on our air sampling practices.  
One of the actions resulting from this assessment was to benchmark utilities on 
use of AMS-4 for general area air sampling and analysis of potential inhalation 
intakes and DAC-HR  assignment to workers.

Browns Ferry does not currently do this as our AMS-4s are used as an indicator 
and we would pull an air sample if necessary.  Does anyone in the industry 
assign DAC-Hrs from a CAM reading?

  ___________________________
        Chuck Creamer
           Charles E. Creamer
        Health Physicist
        Tennessee Valley Authority
        Browns Ferry Nuclear Plant
        P.O. Box 2000 (Mail Stop NAB-1G-BFN)
        Decatur, Al. 35609-2000
        Phone: 256-729-2983
        Fax:  256-729-3101
        Pager: 1-800-323-4853, pin 30-053
          mailto:[email protected]



CONFIDENTIALITY NOTICE:  This electronic message contains
information which may be legally confidential and/or privileged and
does not in any case represent a firm ENERGY COMMODITY bid or offer
relating thereto which binds the sender without an additional
express written confirmation to that effect.  The information is
intended solely for the individual or entity named above and access
by anyone else is unauthorized.  If you are not the intended
recipient, any disclosure, copying, distribution, or use of the
contents of this information is prohibited and may be unlawful.  If
you have received this electronic transmission in error, please
reply immediately to the sender that you have received the message
in error, and delete it.  Thank you.

<<inline: image001.jpg>>

Reply via email to