At STP, our emergency response EPDs are set to 500 mrem and 1000 mrem/h.
Regards, Leonard Earls Consulting Engineer 361-972-7759 ________________________________ From: [email protected] [mailto:[email protected]] On Behalf Of [email protected] Sent: Thursday, April 26, 2012 10:40 To: [email protected] Subject: Powernet: 2nd request Emergency Response RWP Dose/Dose Rate Setpoints Hi, I only received 2 responses (Palo Verde, St. Lucie) on this benchmarking question for SONGS. I was hoping to get a few more data points so I'm sending out again. We have on our emergency response RWP PED setpoints of 100mrem, 700 mrem/hr for HRA and 500 mrem, 7500 mrem/hr for LHRA. Thanks, Sandy Sandra Sewell Health Physics Technical Support San Onofre Nuclear Generating Station (949) 368-9111 PAX 89-111 __________________ SONGS is benchmarking other facilities to determine what their dose and dose rate setpoints are for emergency response RWPs. Thanks, Sandy Sandra Sewell Health Physics Technical Support San Onofre Nuclear Generating Station (949) 368-9111 PAX 89-111 ----------------------------------- Powernet - a service of the Health Physics Society Power Reactor Section Powernet archives at http://www.mail-archive.com/[email protected]/ Reply to: [email protected] If Questions, contact Mike Russell, CHP at [email protected]