Got an odd question on releases in emergency
exercises/events. It's pretty easy to declare that a release has
started - you have effluent monitors and/or field teams. But how
do you determine when a release has stopped if it's unmonitored? The
field team may have confusing data due to ground deposition. Anyone
have a handy thumb-rule? Like - if open window/closed window readings
are the same at ground level and waist level? Or open minus closed
at ground level = zero, you claim no deposition? If you're pressed
for time to declare a release has been terminated, you might not be able
to wait for marinellis to be taken and counted back in a lab. Anyone
have something good in their pocket already?
Thanks, Eric
Eric M. Goldin, CHP
Southern California Edison
<[email protected]>
-----------------------------------
Powernet - a service of the Health Physics Society Power Reactor Section
Powernet archives at http://www.mail-archive.com/[email protected]/
Reply to: [email protected]
If Questions, contact Mike Russell, CHP at [email protected]
- Powernet: EP question on releases Eric . Goldin
- RE: Powernet: EP question on releases Gordon.Nelson
- RE: [Marketing Mail] Powernet: EP question on releas... Burtoff, Charles