For the Argos 5AB we use the following two sources
Tc-99 source (45,000 dpm to 55,000 dpm) 1 inch Am-241 (44,100 dpm to 53,900 dpm) on contact Chuck Creamer Charles E. Creamer Health Physicist Tennessee Valley Authority Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 Phone: 256-729-2983 Fax: 256-729-3101 Pager: 1-800-323-4853, pin 30-053 mailto:[email protected] <mailto:[email protected]> This electronic message transmission contains information which may be TVA SENSITIVE, TVA RESTRICTED or TVA CONFIDENTIAL. Any misuse or unauthorized disclosure can result in both civil and criminal penalties. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the content of this information is prohibited. If you have received this communication in error, please notify me immediately by email and delete the original message. -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of [email protected] Sent: Monday, April 29, 2013 7:32 AM To: [email protected] Subject: Powernet: Calibration of PCMs Hello all, Davis Besse would appreciate answers to the following questions regarding personnel contamination monitors: 1. At what distance from the detector do you calibrate your PCMs? (contact, 1 inch, 3 inches) 2. What isotope and activity source do you use for calibration? Thank you in advance! Claudia L. Sacha RP Services Supervisor [email protected] <mailto:[email protected]> Phone: 419-321-7303 Davis Besse Nuclear Power Station ----------------------------------------- The information contained in this message is intended only for the personal and confidential use of the recipient(s) named above. If the reader of this message is not the intended recipient or an agent responsible for delivering it to the intended recipient, you are hereby notified that you have received this document in error and that any review, dissemination, distribution, or copying of this message is strictly prohibited. If you have received this communication in error, please notify us immediately, and delete the original message. ----------------------------------- Powernet - a service of the Health Physics Society Power Reactor Section Powernet archives at http://www.mail- <http://www.mail-> archive.com/[email protected]/ <mailto:archive.com/[email protected]/> Reply to: [email protected] <mailto:[email protected]> If Questions, contact Mike Russell, CHP at [email protected] <mailto:[email protected]>