Ginna is same as Comanche and TVA - Cs-137 for gamma and Tc-99 for beta Stephen J Holmes, CHP, PE Sr. Plant Health Physicist, CENG-RE Ginna NPP [email protected] 585-771-3577
From: [email protected] [mailto:[email protected]] On Behalf Of Macho, Michael Sent: Monday, July 01, 2013 1:52 PM To: '[email protected]' Subject: RE: Powernet: Calibration and Source Check sources Same as TVA... based on average Unit 1 and Unit 2 energy and DAW activity. Mike Macho RP Supervisor Comanche Peak Nuclear Power Plant Luminant Power, EFH P.O. Box 1002, MC O05A 6322 N FM56 GLEN ROSE, TEXAS 76043 [email protected]<mailto:[email protected]> (254) 897-5698 From: [email protected] [mailto:[email protected]] On Behalf Of Rolph, James Thomas Jr Sent: Monday, July 01, 2013 12:49 PM To: [email protected] Subject: RE: Powernet: Calibration and Source Check sources TVA Sequoyah's response From: [email protected]<mailto:[email protected]> [mailto:[email protected]] On Behalf Of Byrum, William F Sent: Monday, July 01, 2013 1:31 PM To: [email protected]<mailto:[email protected]> Subject: Powernet: Calibration and Source Check sources Duke Energy would like to know the following: Source isotope(s) used for calibration of: 1. Portal Monitors (Cs-137) 2. Personnel Contamination Monitors (Tc99) 3. Tool Monitors (SAMs) (Cs-137) Source isotope(s) used for daily/weekly source checks of: (same radionuclides used for calibration) 1. Portal Monitors 2. Personnel Contamination Monitors 3. Tool Monitors (SAMs) I am sure these have been asked before, if anyone has a current table of responses you can forward them directly to me, otherwise I will tabulate the results and distribute. Bill Byrum, CHP,RSO EnRad Laboratories Duke Energy [email protected]<mailto:[email protected]> Phone: 980.875.5811 Cell Ph.: 704.996.6906 Confidentiality Notice: This email message, including any attachments, contains or may contain confidential information intended only for the addressee. If you are not an intended recipient of this message, be advised that any reading, dissemination, forwarding, printing, copying or other use of this message or its attachments is strictly prohibited. If you have received this message in error, please notify the sender immediately by reply message and delete this email message and any attachments from your system. This e-mail and any attachments are confidential, may contain legal, professional or other privileged information, and are intended solely for the addressee. If you are not the intended recipient, do not use the information in this e-mail in any way, delete this e-mail and notify the sender. -EXCIP
<<inline: image002.gif>>