Cook posts at 90% (90 mRem/hr) and does have that direction contained within a procedure.
4.1.3 Radiation Area (RA) * Post as a "RA" when the general area dose rates are greater than or equal to 4.5 mrem/hr at 30 cm but less than 90 mrem/hr at 30 cm. 4.1.4 High Radiation Area (HRA) [Ref. 7.2.1.e] * Post as a "HRA" when general area dose rates are greater than or equal to 90 mrem/hr at 30 cm but less than 900 mrem/hr at 30 cm. 4.1.5 Locked High Radiation Area (LHRA) * Post as a "LHRA" when general area dose rates are greater than or equal to 900 mrem/hr at 30 cm but less than 500 rads/hr at 1 meter. 4.1.6 Very High Radiation Area (VHRA) * Post as a "VHRA" when the general area dose rates are greater than or equal to 500 rads/hr at 1 meter. From: [email protected] [mailto:[email protected]] On Behalf Of Johns, Alex M. Sent: Saturday, April 26, 2014 6:18 AM To: [email protected] Subject: RE: Powernet: HRA Area Posting This is an EXTERNAL email. STOP. THINK before you CLICK links or OPEN attachments. ________________________________ Salem / Hope Creek posts at 80%. From: [email protected]<mailto:[email protected]> [mailto:[email protected]] On Behalf Of [email protected]<mailto:[email protected]> Sent: Friday, April 25, 2014 6:20 PM Cc: Johnson, David S; [email protected]<mailto:[email protected]>; '[email protected]' Subject: Re: Powernet: HRA Area Posting SONGS posts at 80%. Jeff Carey General Supervisor of Radiation Protection San Onofre Nuclear Generating Station Internal: 949-368-7545 Blackberry: 949-433-0017 x87545/87722 Pony mail: SONGS-J72 From: "Creamer, Charles E" <[email protected]<mailto:[email protected]>> To: "'[email protected]'" <[email protected]<mailto:[email protected]>>, Cc: "Johnson, David S" <[email protected]<mailto:[email protected]>> Date: 04/25/2014 10:53 AM Subject: Powernet: HRA Area Posting Sent by: [email protected]<mailto:[email protected]> ________________________________ [cid:[email protected]] Browns Ferry currently has a statement in procedure recommending posing a High Rad Area at 80% (80 mrem/ hr). Does your station have such a provision in their procedures Chuck Creamer Charles E. Creamer Health Physicist Tennessee Valley Authority Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 Phone: 256-729-2983 Fax: 256-729-3101 Pager: 1-800-323-4853, pin 30-053 mailto:[email protected] REMEMBER - You don't know what you don't know This electronic message transmission contains information which may be TVA SENSITIVE, TVA RESTRICTED or TVA CONFIDENTIAL. Any misuse or unauthorized disclosure can result in both civil and criminal penalties. If you are not the intended recipient, be aware that any disclosure, copying, distribution or use of the content of this information is prohibited. If you have received this communication in error, please notify me immediately by email and delete the original message. ________________________________ The information contained in this e-mail, including any attachment(s), is intended solely for use by the named addressee(s). If you are not the intended recipient, or a person designated as responsible for delivering such messages to the intended recipient, you are not authorized to disclose, copy, distribute or retain this message, in whole or in part, without written authorization from PSEG. This e-mail may contain proprietary, confidential or privileged information. If you have received this message in error, please notify the sender immediately. This notice is included in all e-mail messages leaving PSEG. Thank you for your cooperation.