Chuck,

Our minimum protective clothing requirement is labcoat, shoe covers and gloves. 
 Our procedures and RWP instructions include the following:

Lab coat, shoe covers, and gloves may be used for entries for observation, 
equipment checks, and routine sampling. Specify on RWP that there shall be no 
climbing, kneeling, or other actions which
might cause contact between contamination and personal clothing.

Barbara J. Thompson
North Anna Power Station
1022 Haley Drive
Mineral, Va 23117
Health Physicist III
[email protected]<mailto:[email protected]>
Phone:  540-894-2638


From: Creamer, Charles E [mailto:[email protected]]
Sent: Wednesday, March 15, 2017 11:20 AM
To: Powernet powernet
Cc: Hocking, Gregory Paul
Subject: [External] [powernet] Limited Dressout Question

Does anyone allow booties and gloves in certain cases such as minor tasks in 
low risk Contaminated Area,  Operator Check tags, checking component UNID, LHRA 
door checks, read a gauge, Change an air sample head, etc.

If so what do your instructions, procedures or RWPs state for these instances?

Chuck Creamer
Charles E. Creamer
Health Physicist
Tennessee Valley Authority
Browns Ferry Nuclear Plant
P.O. Box 2000 (Mail Stop NAB-1G-BFN)
Decatur, Al. 35609-2000
Phone: 256-729-2983
Fax:  256-729-3101
Pager: 1-800-323-4853, pin 30-053
mailto:[email protected]


This electronic message transmission contains information which may be TVA 
SENSITIVE, TVA RESTRICTED or TVA CONFIDENTIAL. Any misuse or unauthorized 
disclosure can result in both civil and criminal penalties. If you are not the 
intended recipient, be aware that any disclosure, copying, distribution or use 
of the content of this information is prohibited. If you have received this 
communication in error, please notify me immediately by email and delete the 
original message.




CONFIDENTIALITY NOTICE:  This electronic message contains information which may 
be legally confidential and or privileged and does not in any case represent a 
firm ENERGY COMMODITY bid or offer relating thereto which binds the sender 
without an additional express written confirmation to that effect.  The 
information is intended solely for the individual or entity named above and 
access by anyone else is unauthorized.  If you are not the intended recipient, 
any disclosure, copying, distribution, or use of the contents of this 
information is prohibited and may be unlawful.  If you have received this 
electronic transmission in error, please reply immediately to the sender that 
you have received the message in error, and delete it.  Thank you.

Reply via email to