1. CANBERRA FSCAN 2. ANNUAL
3. SHIFTLY (12 HOURS) 4. NO Michael Macho Radiation Protection Staff [email protected] [cid:[email protected]] SAFETY is first QUALITY SCHEDULE Luminant Power Comanche Peak Nuclear Power Plant 6322 North FM 56 or PO Box 1002 Mail Code 005A Glen Rose, TX 76043 (254)897-5698 /(254)897-8163 (817)559-1997 Cell From: Derek Hultquist [mailto:[email protected]] Sent: Wednesday, April 26, 2017 2:07 PM To: [email protected] Subject: [powernet] Quick Whole Body Counter Performance Benchmark EXTERNAL EMAIL Hi, D. C. Cook is looking at streamlining our process for maintaining the whole-body counters on-site. We would like to know the following. 1. What whole body counters do you use? 2. What is your calibration frequency for whole body counters? 3. What is your frequency for performing a source check on the whole body counters? 4. Do you perform cross-checks (counting an unknown source to be compared to an accredited lab) on the whole body counters? If so, at what frequency? Thanks for your assistance! Derek Hultquist Health Physicist D. C. Cook NPP (269) 465-5901 x2088