Duke Energy does not use the Alpha 6 CAM's. We currently use the AMS-4 Beta 
CAM's and will soon be implementing the Canberra iCAM alpha/beta CAM's fleet 
wide.

Thanks,
Bill Faulkenberry, NRRPT
Supervising Scientist, EnRad Labs
Duke Energy
13339 Hagers Ferry Rd
Mail Stop MG03A2
Huntersville, NC  28078
Office: 980-875-6893
Mobile: 803-627-4832

-----Original Message-----
From: Sandy Voss [mailto:[email protected]] 
Sent: Wednesday, July 19, 2017 10:19 AM
To: [email protected]
Cc: [email protected]
Subject: [powernet] [Fwd: Alpha 6 CAMs at Idaho National Lab]



*** Exercise caution. This is an EXTERNAL email. DO NOT open attachments or 
click links from unknown senders or unexpected email. ***

Everyone

how many of you use the Eberline Alpha-6 CAMs ?

how many Alpha-6 CAMs do you operate ?

I started using them at WIPP in 1989 when they were transitioning from the NRC 
REM-RAD CAMs there.

The Alpha-6 communications software was written for 32 bits and will not run on 
a 64 bit computer.

The original program developer is still working in the radiation detector field 
and might be willing to rewrite that original software to work with
64 bit computers.  Perhaps another programmer could take on that project.

Outside cal labs could calibrate the Alpha-6 for you but that might not fit 
into your quality control programs.

Here at LANL we addressed the RF interference difficulty by making simple 
Farady cages.  Then we also changed the silicon diffused junction detectors to 
either Canberra PIPS or Ortec SB detectors.

I always found the Alpha-6s to be very easy to use and understand and I also 
made some modifications to the alpha analysis programming which led to new 
chips being programmed for those Alpha-6s.

So, if you have some answers or questions please let Andrew know and certainly 
let the rest of us powernet list server individuals know.

best regards

Tom


---------------------------- Original Message ----------------------------
Subject: Alpha 6 CAMs at Idaho National Lab
From:    "Newman, Andrew D" <[email protected]>
Date:    Tue, July 18, 2017 2:17 pm
To:      "[email protected]" <[email protected]>
--------------------------------------------------------------------------

We are still using Alpha-6 CAMs, have run into a problem and wonder if you guys 
have found a way around this.  Our CAM calibration computers run on Windows XP 
which is no longer supported by either our company or Microsoft.  One of our 
calibration CAMs died and our IT people will not reload Windows XP on it.  And 
the software for Alpha-6 calibration only runs on Windows XP.  Thermo  Eberline 
told us the Alpha 6 software is not available on Windows 7 as it is outdated.

Is there an updated version of the software to calibrate the Alpha 6 CAMs?

Thanks

Andy Newman CHP
Fluor Idaho


Andrew Newman  Health Physicist  Fluor Idaho  1580 Sawtelle St., Idaho 
Falls, ID  83402, MS-XXXX   [email protected]<mailto:[email protected]>   O 
208-533-3517   M 208-241-9588   
www.Fluor-Idaho.com<http://www.fluor-idaho.com/>



Powernet - a service of the Health Physics Society Power Reactor Section

To post message: Send or Reply to: [email protected]
To unsubscribe: send message to [email protected]
archive(Nov2015->): http://www.mail-archive.com/[email protected]/
archive(<Oct2015): http://www.mail-archive.com/[email protected]/
If questions, contact E. Scott Medling, CHP at [email protected]

Reply via email to