All, I'm looking for any actual or planned radiological monitoring during cask/fuel drying operations. In particular, monitoring of the gas flow path from the cask to the installed building exhaust plenum(s).
The object of this exercise is to ensure that we have sufficient data to accurately quantify any gas release should a fuel pin breach during the drying operations. The Feb. 2018 Information Notice (IN-18-01) and how we deal with that information is driving this. Our current thinking is to install a real-time monitor, as well as discrete sampling capability on the fuel-drying system's effluent line. This is in addition to the installed stack monitors & sample points. Thoughts? Thank you, David Brehm Sr. Radiological Engineer Radiation Protection - Fort Calhoun Station Omaha Public Power District FC-3-1 9610 Power Lane, Blair, NE 68008 Office: 402.533.6045 Cellular: 402.237.9840 [email protected]<mailto:[email protected]>
_______________________________________________ Powernet mailing list [email protected] http://hpspowernet.org/mailman/listinfo/powernet_hpspowernet.org