All,

I'm looking for any actual or planned radiological monitoring during cask/fuel 
drying operations.  In particular, monitoring of the gas flow path from the 
cask to the installed building exhaust plenum(s).

The object of this exercise is to ensure that we have sufficient data to 
accurately quantify any gas release should a fuel pin breach during the drying 
operations.  The Feb. 2018 Information Notice (IN-18-01) and how we deal with 
that information is driving this.

Our current thinking is to install a real-time monitor, as well as discrete 
sampling capability on the fuel-drying system's effluent line.  This is in 
addition to the installed stack monitors & sample points.

Thoughts?

Thank you,

David Brehm
Sr. Radiological Engineer
Radiation Protection - Fort Calhoun Station
Omaha Public Power District
FC-3-1
9610 Power Lane, Blair, NE 68008
Office: 402.533.6045
Cellular: 402.237.9840
[email protected]<mailto:[email protected]>
_______________________________________________
Powernet mailing list
[email protected]
http://hpspowernet.org/mailman/listinfo/powernet_hpspowernet.org

Reply via email to