Fermi has a 10% bias on SRD (DMC2000/3000). We see about 3% return.
From: Powernet [mailto:[email protected]] On Behalf Of Williams, Michelle Lewis via Powernet Sent: Thursday, June 28, 2018 10:50 AM To: [email protected] Cc: Williams, Michelle Lewis <[email protected]> Subject: [EXTERNAL] [Powernet] Calibration bias between SRD and DLR benchmarking question Do you use a calibration bias between your SRD and DLR? If so what percent is it? How much of a return do you see once you have completed your DLR exchange? Vogtle 1&2 currently has a calibration bias of 17% on our SRD (DMC 3000) as compared to our DLR (OSLN). We currently see a return of 14% of dose once we have our DLR's exchanged and read as compared to the SRD estimates Michelle Williams RP Superintendent Support Services Plant Vogtle Units 1&2 706.848.4236 tel 919.770.7138 cell [southern_nucl_h_rgb]