he he he... iya ya... betul joega. thanx anyway mas sodik. udah bisa.

--- In [email protected], "Sodik Ihwan" <[EMAIL PROTECTED]> 
wrote:
>
> pake fungsi mid aja mas, outputnya kan text biasa...
> salam,
> sodik
> 
> On Wed, 07 May 2008 08:56:42 +0700, Noe <[EMAIL PROTECTED]> wrote:
> 
> >
> > dear all
> >
> > saya sedang membuat software untuk membaca timbangan. komponen 
yang
> > digunakan adalah MsComm (VB Poenya). output dari timbangan ke 
kompi
> > seperti ini :
> >
> > US,NT,+ 000000 KG
> >
> > gimana caranya ya biar yang dibaca hanya 000000 saja. berikut di 
bawah
> > ini contoh script yang digunakan :
> >
> >   Private Sub Form_Load()
> >
> >
> >   Form1.Caption = "App2"
> >   With MSComm1
> >   .CommPort = 2
> >   .Handshaking = 2 - comRTS
> >   .RThreshold = 1
> >   .RTSEnable = True
> >   .Settings = "9600,n,8,1"
> >   .SThreshold = 1
> >   .PortOpen = True
> >   ' Leave all other settings as default values.
> >   End With
> >   Text1.Text = ""
> >
> >
> >   End Sub
> >
> >   Private Sub Form_Unload(Cancel As Integer)
> >
> >
> >   MSComm1.PortOpen = False
> >
> >
> >   End Sub
> >
> >   Private Sub MSComm1_OnComm()
> >   Dim InBuff As String
> >
> >   Select Case MSComm1.CommEvent
> >   ' Handle each event or error by placing
> >   ' code below each case statement.
> >
> >   ' This template is found in the Example
> >   ' section of the OnComm event Help topic
> >   ' in VB Help.
> >
> >   ' Errors
> >   Case comEventBreak ' A Break was received.
> >   Case comEventCDTO ' CD (RLSD) Timeout.
> >   Case comEventCTSTO ' CTS Timeout.
> >   Case comEventDSRTO ' DSR Timeout.
> >   Case comEventFrame ' Framing Error.
> >   Case comEventOverrun ' Data Lost.
> >   Case comEventRxOver ' Receive buffer overflow.
> >   Case comEventRxParity ' Parity Error.
> >   Case comEventTxFull ' Transmit buffer full.
> >   Case comEventDCB ' Unexpected error retrieving DCB]
> >
> >   ' Events
> >   Case comEvCD ' Change in the CD line.
> >   Case comEvCTS ' Change in the CTS line.
> >   Case comEvDSR ' Change in the DSR line.
> >   Case comEvRing ' Change in the Ring Indicator.
> >
> >
> >   Case comEvReceive ' Received RThreshold # of chars.
> >
> >
> >   InBuff = MSComm1.Input
> >   Call HandleInput(InBuff)
> >
> >
> >   Case comEvSend ' There are SThreshold number of
> >   ' characters in the transmit buffer.
> >   Case comEvEOF ' An EOF character was found in the
> >   ' input stream.
> >   End Select
> >
> >   End Sub
> >
> >   Sub HandleInput(InBuff As String)
> >
> >
> >   ' This is where you will process your input. This
> >   ' includes trapping characters, parsing strings,
> >   ' separating data fields, etc. For this case, you
> >   ' are simply going to display the data in the TextBox.
> >   Text1.SelStart = Len(Text1.Text)
> >   Text1.SelText = InBuff
> >
> >
> >   End Sub
> >
> >
> >
> > mohon bantuannya
> >
> > NOE
> >
> >
> >
> 
> 
> 
> -- 
> Using Opera's revolutionary e-mail client: http://www.opera.com/
mail/
> 
> Send instant messages to your online friends http://
asia.messenger.yahoo.com
>


Kirim email ke