Hi Samuele, Thanks for your information. I will wait for the new release. Peony
-----Original Message----- From: Samuele Kaplun [mailto:[email protected]] Sent: Monday, February 23, 2009 6:07 PM To: [email protected] Cc: [email protected] Subject: Re: bibindex problem Dear Tai, In data Monday 23 February 2009, Tai Lum scribacchiaste dette parole: > Error: Cannot read > http://techreports.lib.berkeley.edu/accessPages/CDS-90-607.html: > <urlopen error (4, 'Interrupted system call')> > Error: Cannot read > http://stat-reports.lib.berkeley.edu/accessPages/115.html: <urlopen > error (4, 'Interrupted system call')> > Error: Cannot read > http://techreports.lib.berkeley.edu/accessPages/CDS-93-726.html: > <urlopen error (4, 'Interrupted system call')> for this specific error, it might be due to a conflict between BibSched and BibIndex when BibIndex is retrieving external URLs. If you're testing CDS Invenio 0.99.1 please note that this has been fixed for the up-coming release and that you can patch your installation too in order to fix this bug. You just need to change a single line in bibtask.py (under /opt/cds- invenio/lib/python/invenio) with: @@ -544,7 +544,7 @@ def _task_run(task_run_fnc): ## initialize signal handler: _task_params['signal_request'] = None signal.signal(signal.SIGUSR1, _task_sig_sleep) - signal.signal(signal.SIGUSR2, _task_sig_ping) + signal.signal(signal.SIGUSR2, signal.SIG_IGN) signal.signal(signal.SIGTSTP, _task_sig_ctrlz) signal.signal(signal.SIGTERM, _task_sig_stop) signal.signal(signal.SIGQUIT, _task_sig_stop) i.e. to change "signal.signal(signal.SIGUSR2, _task_sig_ping)" into "signal.signal(signal.SIGUSR2, signal.SIG_IGN)". Best regards, Samuele -- Samuele Kaplun ** CERN Document Server ** <http://cds.cern.ch/>