On 17 Mar 15:58, Thomas Rodriguez wrote:
> 
> Hello,
> 
> I want to send alert in a different way for a different time period.
> For that I installed 2 alertmanager (alertmanager-ho and alertmanager-hno).
> I put inhibitor for alertmanager-ho during night and inhibitor for 
> alertmanager-hno during day.
> 
> If I put theses 2 alertmanager in cluster mode. What will hapend? How the 
> alertmanager will be chosen?  Do we have an other way for sending I silence 
> in 2 alertmanager ?
> 
> I am following the right way for what I want to do?

Hello,

The best way to achieve what you want is to use continue: true in your
routing tree.

> 
> Thanks,
> Thomas
> 
> -- 
> You received this message because you are subscribed to the Google Groups 
> "Prometheus Users" group.
> To unsubscribe from this group and stop receiving emails from it, send an 
> email to [email protected].
> To view this discussion on the web visit 
> https://groups.google.com/d/msgid/prometheus-users/e5e2d182-a715-4ce7-a488-5882a09c2244n%40googlegroups.com.


-- 
Julien Pivotto
@roidelapluie

-- 
You received this message because you are subscribed to the Google Groups 
"Prometheus Users" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/prometheus-users/20210317230245.GA347454%40oxygen.

Reply via email to