I have a new device that reports its SNMP values as hex byte strings
encoded using IEEE-754.
For example the value "423ce042" means 47.219.

This was proposed as a textual convention in RFC6340 but it’s the first
time I’ve come across it.
https://www.rfc-editor.org/rfc/rfc6340

As far as I can tell, snmp-exporter cannot decode this format. Would this
be a worthwhile feature to add, or would I be better off writing a custom
exporter for this device?

If you’re curious, the device is a cinema calibration tool from HSG Labs.
https://hsg-labs.com/ultimate.html

-- 
You received this message because you are subscribed to the Google Groups 
"Prometheus Users" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to prometheus-users+unsubscr...@googlegroups.com.
To view this discussion visit 
https://groups.google.com/d/msgid/prometheus-users/CALajkdg8M67gRZUiRUJPjXmCr5o3y2ETM%3DEvi_GGiCdPgGSbMw%40mail.gmail.com.

Reply via email to