Hi,

On Thu, Dec 01, 2016 at 05:00:19PM +0100, Clemens Gruber wrote:
> On Tue, Nov 29, 2016 at 09:46:14AM +0100, Michael Olbrich wrote:
> > On Mon, Nov 28, 2016 at 06:02:51PM +0100, Clemens Gruber wrote:
> > > did you already start working on updating systemd to version 232?
> > 
> > I've started with it. But new systemd versions require more testing than
> > most packages.
> 
> I just tried the ptxdist master version of systemd 232.
> 
> Looking good except for one problem:
> rc-once.service: Main process exited, code=killed, status=15/TERM
> rc-once.service: Unit entered failed state.
> rc-once.service: failed with result 'signal'.
> 
> Because I am not doing anything different in /etc/rc.once.d/*, I assume
> this has something to do with the update from 231 to 232.
> 
> Can you reproduce this?
> 
> For the record, in rc.once.d I have: ldconfig, machine-id and openssh.
> 
> Is there something in /lib/systemd/systemd-rc-once which could cause
> this on systemd 232?

I'm not aware of anything that would cause this. I just tried this
combination in my qemu test BSP and it works without problems.

Do you get a emergency shell? Anything else in the journal? How long does
it take to get the error? Maybe the service is killed by a timeout.

Michael

-- 