On 28.09.20 10:36, Mira Limbeck wrote: > After migration or a rollback the cloudinit disk might not be allocated, so > volume_size_info() fails. As we override the value anyway for cloudinit > and efi disks simply move the volume_size_info() call into the 'else' > branch. > > Signed-off-by: Mira Limbeck <[email protected]> > --- > v2: changed subject > > PVE/QemuServer.pm | 4 +++- > 1 file changed, 3 insertions(+), 1 deletion(-) > > diff --git a/PVE/QemuServer.pm b/PVE/QemuServer.pm > index 2747c66..49765b7 100644 > --- a/PVE/QemuServer.pm > +++ b/PVE/QemuServer.pm > @@ -6895,10 +6895,10 @@ sub clone_disk { > $storeid = $storage if $storage; > > my $dst_format = resolve_dst_disk_format($storecfg, $storeid, $volname, > $format); > - my ($size) = PVE::Storage::volume_size_info($storecfg, $drive->{file}, > 3); > > print "create full clone of drive $drivename ($drive->{file})\n"; > my $name = undef; > + my $size = undef; > if (drive_is_cloudinit($drive)) { > $name = "vm-$newvmid-cloudinit"; > $name .= ".$dst_format" if $dst_format ne 'raw'; > @@ -6906,6 +6906,8 @@ sub clone_disk { > $size = PVE::QemuServer::Cloudinit::CLOUDINIT_DISK_SIZE; > } elsif ($drivename eq 'efidisk0') { > $size = get_efivars_size($conf); > + } else { > + ($size) = PVE::Storage::volume_size_info($storecfg, $drive->{file}, > 3); > } > $size /= 1024;
doesn't this logs a "use of undefined value in division" or something like that somewhere in the non-else case? > $newvolid = PVE::Storage::vdisk_alloc($storecfg, $storeid, $newvmid, > $dst_format, $name, $size); > _______________________________________________ pve-devel mailing list [email protected] https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-devel