Am 09.01.2018 um 14:36 schrieb Alexandre DERUMIER: >>> i've the first customers having impacts. Current badest example: instead >>> of 12% cpu load 75% cpu load in guest. > > Just curious, what kind of workload ?
MySQL only - small blocks > I think with ceph and librbd, it'll hurt too for small block. Yes i'm booting ceph as well with pti=off / have no updated them at all. > (I think I'll disable the patch cluster/osd side, as it's in a secure > network, but client side will be impacted) So the problem in my case is completely client impacted. Greets, Stefan > > ----- Mail original ----- > De: "Stefan Priebe, Profihost AG" <s.pri...@profihost.ag> > À: "aderumier" <aderum...@odiso.com> > Cc: "pve-devel" <pve-devel@pve.proxmox.com> > Envoyé: Mardi 9 Janvier 2018 14:32:27 > Objet: Re: [pve-devel] cpuflag: pcid needed in guest for good performance > after meltdown > > Am 09.01.2018 um 14:24 schrieb Alexandre DERUMIER: >> ok thanks ! > > i've the first customers having impacts. Current badest example: instead > of 12% cpu load 75% cpu load in guest. > >> ----- Mail original ----- >> De: "Stefan Priebe, Profihost AG" <s.pri...@profihost.ag> >> À: "aderumier" <aderum...@odiso.com> >> Cc: "pve-devel" <pve-devel@pve.proxmox.com> >> Envoyé: Mardi 9 Janvier 2018 14:10:27 >> Objet: Re: [pve-devel] cpuflag: pcid needed in guest for good performance >> after meltdown >> >> Am 09.01.2018 um 13:02 schrieb Alexandre DERUMIER: >>>>> You mean: >>>>> -cpu qemu64,+pcid >>> >>> yes. >>> >>> (don't known the perf difference between qemu64 (without pcid), and intel >>> cpu model (without pcid too) ? ) >> >> The results are nearly the same. >> >> Same VM as before now model qemu64,+pcid: >> real 0m13.870s >> user 0m7.128s >> sys 0m6.697s >> >> qemu64: >> real 0m25.214s >> user 0m16.923s >> sys 0m8.956s >> >> Stefan >>> >>> ----- Mail original ----- >>> De: "Stefan Priebe, Profihost AG" <s.pri...@profihost.ag> >>> À: "aderumier" <aderum...@odiso.com> >>> Cc: "pve-devel" <pve-devel@pve.proxmox.com> >>> Envoyé: Mardi 9 Janvier 2018 12:57:30 >>> Objet: Re: [pve-devel] cpuflag: pcid needed in guest for good performance >>> after meltdown >>> >>> Am 09.01.2018 um 12:55 schrieb Alexandre DERUMIER: >>>>>> Yes - see an example which does a lot of syscalls: >>>> >>>> and for qemu64 ? (is it possible to sent +pcid too ?) >>> >>> You mean: >>> -cpu qemu64,+pcid >>> ? >>> >>> Stefan >>> >>>> ----- Mail original ----- >>>> De: "Stefan Priebe, Profihost AG" <s.pri...@profihost.ag> >>>> À: "aderumier" <aderum...@odiso.com> >>>> Cc: "pve-devel" <pve-devel@pve.proxmox.com> >>>> Envoyé: Mardi 9 Janvier 2018 12:20:04 >>>> Objet: Re: [pve-devel] cpuflag: pcid needed in guest for good performance >>>> after meltdown >>>> >>>> Am 09.01.2018 um 10:43 schrieb Alexandre DERUMIER: >>>>>>> That's bad as pcid is very important to performance for meltdown fixes >>>>>>> in the linux kernel. >>>>> >>>>> I wonder the difference of performance for >>>>> >>>>> - qemu64|kvm64 cpu model >>>>> - intel cpu model >>>>> - intel + pcid cpu model ? >>>>> >>>>> (currently I'm running mainly qemu64 because I don't need advanced cpu >>>>> flag) >>>>> >>>>> Do you have already done some benchmarks ? >>>> >>>> >>>> Yes - see an example which does a lot of syscalls: >>>> >>>> no tasks running other than du: >>>> >>>> no pcid: >>>> # time for i in $(seq 1 1 50); do du -sx /; done >>>> ... >>>> real 0m26.614s >>>> user 0m17.548s >>>> sys 0m9.056s >>>> >>>> >>>> kvm started with +pcid: >>>> # time for i in $(seq 1 1 50); do du -sx /; done >>>> ... >>>> real 0m14.734s >>>> user 0m7.755s >>>> sys 0m6.973s >>>> >>>> Greets, >>>> Stefan >>>> >>>>> >>>>> ----- Mail original ----- >>>>> De: "Stefan Priebe, Profihost AG" <s.pri...@profihost.ag> >>>>> À: "aderumier" <aderum...@odiso.com> >>>>> Cc: "pve-devel" <pve-devel@pve.proxmox.com> >>>>> Envoyé: Mardi 9 Janvier 2018 10:20:39 >>>>> Objet: Re: [pve-devel] cpuflag: pcid needed in guest for good performance >>>>> after meltdown >>>>> >>>>> Am 09.01.2018 um 09:18 schrieb Alexandre DERUMIER: >>>>>> they are a discussion on qemu mailing currently about pcid >>>>>> >>>>>> >>>>>> From paolo bonzini: >>>>>> >>>>>> " >>>>>> Note that PCID is still not supported for guests without EPT, so >>>>>> this would break ept=0 with recent "-cpu" models. I'm not sure of >>>>>> a way to fix it; probably it just has to be documented." >>>>> >>>>> That's bad as pcid is very important to performance for meltdown fixes >>>>> in the linux kernel. >>>>> >>>>> Stefan >>>>> >>>>>> >>>>>> ----- Mail original ----- >>>>>> De: "Stefan Priebe, Profihost AG" <s.pri...@profihost.ag> >>>>>> À: "pve-devel" <pve-devel@pve.proxmox.com>, "aderumier" >>>>>> <aderum...@odiso.com> >>>>>> Envoyé: Mardi 9 Janvier 2018 08:35:00 >>>>>> Objet: Re: [pve-devel] cpuflag: pcid needed in guest for good >>>>>> performance after meltdown >>>>>> >>>>>> Am 08.01.2018 um 23:23 schrieb Alexandre DERUMIER: >>>>>>> I think it's not exposed in current cpu model >>>>>>> >>>>>>> it can be enabled with "+pcid" >>>>>>> >>>>>>> >>>>>>> I don't known what it's the best way to add it in proxmox. >>>>>>> We could do it with qemu version upgrade, but qemu 2.10 are not ready. >>>>>> >>>>>> Yes but that was always bad at least to me. We're limiting ourselfes if >>>>>> we can only add new qemu features with a new qemu version. >>>>>> >>>>>> What about a version or feature field in the guest config which we only >>>>>> update on a fresh vm start. >>>>>> >>>>>> Something like this: >>>>>> 123.conf: >>>>>> ... >>>>>> pve_qemu_version: 2.11-10 >>>>>> ... >>>>>> >>>>>> This field is ONLY and ALWAYS updated in a fresh start not on migration. >>>>>> This can be easily detected. >>>>>> >>>>>> Than we can do stuff like >>>>>> if (version_cmp($conf->{pve_qemu_version}, "2.11-11")) { >>>>>> # enable pcid flag >>>>>> } >>>>>> >>>>>> Greets >>>>>> Stefan >>>>>> >>>>>>> Maybe add new cpumodel with +pcid enabled ? >>>>>>> or add code to manage custom cpuflags and add a checkbox in cpu options >>>>>>> ? >>>>>>> >>>>>>> >>>>>>> >>>>>>> ----- Mail original ----- >>>>>>> De: "Stefan Priebe, Profihost AG" <s.pri...@profihost.ag> >>>>>>> À: "pve-devel" <pve-devel@pve.proxmox.com> >>>>>>> Envoyé: Lundi 8 Janvier 2018 21:34:57 >>>>>>> Objet: [pve-devel] cpuflag: pcid needed in guest for good performance >>>>>>> after meltdown >>>>>>> >>>>>>> Hello, >>>>>>> >>>>>>> for meltdown mitigation and performance it's important to have the pcid >>>>>>> flag passed down to the guest (f.e. >>>>>>> https://groups.google.com/forum/m/#!topic/mechanical-sympathy/L9mHTbeQLNU). >>>>>>> >>>>>>> >>>>>>> My host shows the flag: >>>>>>> # grep ' pcid ' /proc/cpuinfo | wc -l >>>>>>> 56 >>>>>>> >>>>>>> But the guest does not: >>>>>>> # grep pcid /proc/cpuinfo >>>>>>> # >>>>>>> >>>>>>> Guest was started with: >>>>>>> -cpu IvyBridge,+kvm_pv_unhalt,+kvm_pv_eoi,enforce,vendor=GenuineIntel >>>>>>> >>>>>>> Is this something missing in host kernel or in PVE? >>>>>>> >>>>>>> Greets, >>>>>>> Stefan >>>>>>> _______________________________________________ >>>>>>> pve-devel mailing list >>>>>>> pve-devel@pve.proxmox.com >>>>>>> https://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-devel >>>>>>> >>>>>>> _______________________________________________ >>>>>>> pve-devel mailing list >>>>>>> pve-devel@pve.proxmox.com >>>>>>> https://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-devel >>>>>>> >>>>>> >>>>> >>>> >>> >> > _______________________________________________ pve-devel mailing list pve-devel@pve.proxmox.com https://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-devel