Hi all,

We have recently changed the storage backend of a Proxmox cluster. It was using softraid with a SSD drive and a iSCSI drive, and we have switched to RBD on a 2 OSD ceph storage.

One of the VMs is quite I/O intensive, as it executes some precalcs between 2 DBs every hour.

Our experience has been as follows:

- 1st SSD OSD (inline journal) was a Intel S3500 300GB . This has been rocking fast from begining to end, a non-dreamt delight suddenly realized. :) Atop reports on peak use ~4% use and 3MB/s write. Much better performance than the old storage.

- 2nd SSD OSD (inline journal) was a Samsung 840 Pro 256GB, used in the old softraid. This has been a pain from the begining; when it was up rebalancing/degradation fix was painfully slow. Finally on peak use it wasn't up to the task, so we had to down it to keep the system doing usable work. We have checked it with Samsung's Magician, its 24.5TBW well bellow 72TBW warranty, but reported performance is bad even after firmware update.

- We replaced the 2nd SSD OSD with a Crucial M550 256GB. This hasn't been too bad; rebalancing was much quicker than with 840pro, and on peak use atop reports ~50% use and 3MB/s write, so we see it up to the task.

Now my thoughts and questions:
- If I look to the spec sheets, 840pro and M550 should give me much better performance than S3500. What's going on? What should I check on specs for "real" performance? :-) - What real use experience do you have with those or other SSDs for Ceph OSDs?

Thanks for reading
Eneko

--
Zuzendari Teknikoa / Director Técnico
Binovo IT Human Project, S.L.
Telf. 943575997
      943493611
Astigarraga bidea 2, planta 6 dcha., ofi. 3-2; 20180 Oiartzun (Gipuzkoa)
www.binovo.es

_______________________________________________
pve-user mailing list
pve-user@pve.proxmox.com
http://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-user

Reply via email to