Hi all,

In our PVE 3.4 cluster, we found a OSD disk was having quite a high amount of errors as reported by SMART, and also quite high wait time as reported by munin, so we decided to replace it.

What I have done is down/out the osd, then remove it (removing partitions). Replace the disk and create a new OSD, which was created with the same ID as the removed one (as I was hoping to not change CRUSH map).

So everything has worked as expected, except one minor non-issue:
- Original OSD journal was on a separate SSD disk, with partitions #1 and #2.
- Original journal partition (#1) was removed
- A new partition has been created as #1, but has been assigned space after the last existing partition. So there is now hole of 5GB in the beginning of SSD disk.

What I'm afraid is that given enough OSD replacements, Proxmox wouldn't find free space for new journals in that SSD disk? Although there would be plenty in the beginning?

Maybe the journal-partition creation can be improved so that it can detect free space also in the beginning and between existing partitions?

Cheers
Eneko

--
Zuzendari Teknikoa / Director Técnico
Binovo IT Human Project, S.L.
Telf. 943575997
      943493611
Astigarraga bidea 2, planta 6 dcha., ofi. 3-2; 20180 Oiartzun (Gipuzkoa)
www.binovo.es

_______________________________________________
pve-user mailing list
[email protected]
http://pve.proxmox.com/cgi-bin/mailman/listinfo/pve-user

Reply via email to