On 09/09/14 19:16, Zhang Wei wrote:
> Dear Dr Peter:
> thanks for your reply. I tried to use parameter but it doesn’t work.
> here is the error message:
> wxw@cu02 test]$ pyfr-sim run  couette_flow_2d.pyfrm couette_flow_2d.ini
> -b openmp 
> [cu02:30246] [[13141,1],0] ORTE_ERROR_LOG: Data for specified key not
> found in file btl_usnic_cclient.c at line 88
> [cu02][[13141,1],0][btl_usnic_cclient.c:89:ompi_btl_usnic_connectivity_client_init]
> usNIC connectivity client unable to db_fetch local leader
> usage: pyfr-sim [-h] [--verbose] [--backend BACKEND] [--progress]
>                 [--nansweep N]
>                 {run,restart} ...
> pyfr-sim: error: unrecognized arguments: -b openmp
> 
> I suppose it is because I don’t have openmp installed on the node if I
> can run serially without this parallel parameter?
> cheers

As per the usage statement the BACKEND argument must come before
run/restart.  Changing the command to

  $ pyfr-sim -b openmp run  couette_flow_2d.pyfrm couette_flow_2d.ini

should sort it out.

Regards, Freddie.