Hi Junting,

On 18/06/2019 21:40, Junting Chen wrote:
> Thanks for the reply. Sorry I am a bit confused by “supersonic inlet”
> you mentioned. I have no intention to introduce compressible flow and
> shock at any point. Those are for sure out of our scope. Is the unit of
> u v and w meter per second? Maybe there is something I missed.

PyFR is dimensionless.  However, within the context of the simulation I
suspect that 0.2 is a reference to the Mach number as opposed to the
velocity in m s^-1.

Regards, Freddie.

-- 
You received this message because you are subscribed to the Google Groups "PyFR 
Mailing List" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send an email to [email protected].
Visit this group at https://groups.google.com/group/pyfrmailinglist.
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/pyfrmailinglist/45f40875-01bf-0dca-bf74-b3293b3d5e64%40witherden.org.
For more options, visit https://groups.google.com/d/optout.

Reply via email to