New submission from STINNER Victor <victor.stin...@haypocalc.com>:

InterProcessSignalTests uses 4 different signal handlers (SIGUSR1, SIGUSR2, 
SIGALRM, SIGHUP) and uses 2 methods to raise a signal (a subprocess executing 
"kill -SIG pid" or signal.alarm(1)). It uses signal.pause() and/or 
time.sleep(1) to wait the signal, or just nothing for SIGUSR2 (configured to be 
ignored).

The testcase tests too many unrelated things.

signal.alarm(1) is not an interprocess signal: it is a signal send to the 
process itself.

Why using two different signal handlers? A modifies a_called, B modifies 
b_called but raise also a Python exception. How is it related to interprocess 
signal handling?

Why checking that the handler A (SIGHUP) has not been called when the signal 
handler B (SIGUSR1) is called?

Why is the garbage collector disabled?

I propose to write a new simple testcase: install a signal handler raising a 
Python exception, send a signal using a child process, ensure that the signal 
has been received (wait for the exception). Pseudo-code:

--------
s = signal.SIGUSR1
def handler(signum, frame): 1/0
signal.signal(s, handler)
try:
  subprocess.call([sys.executable, '-c', '... kill(%s, %s)' % (os.getpid(), s))
  ... wait the signal ...
except ZeroDivisionError:
  pass
else:
  raise Exception("ZeroDivisionError not raised"
--------

The whole test has to be run in a subprocess.

The new test may pass on freebsd 6, it should be checked (see issue #12469).

----------
components: Tests
messages: 139813
nosy: haypo, neologix
priority: normal
severity: normal
status: open
title: Rewrite InterProcessSignalTests
versions: Python 3.3

_______________________________________
Python tracker <rep...@bugs.python.org>
<http://bugs.python.org/issue12495>
_______________________________________