On 03/04/13 11:51, Marco Nawijn wrote:
Hello Uwe,
I have no answer for you at this moment, but just out of curiosity, why
do you want to
convert from BDF to STEP?
Marco
P.S. Note that there is a specific STEP standard (AP 209) for data
exchange between
CAD and FEA. I don't know if this is supported by OCC at all though
Marco,
data exchange between CAD and FEA is exactly the reason I want to do
this conversion. Many thanks to you and Thomas for the AP 209
suggestion, I will look into it.
As Thomas mentioned in his e-mail, STEP AP209 is supported by occt, but
the python wrapper is missing from pythonocc. We've just found out that
it is possible to do this with Patran though, which is sufficient for now.
Thanks,
Uwe
--
Uwe Schlifkowitz -- Software Engineer
INTALES GmbH Engineering Solutions
Innsbrucker Str. 1
A-6161 Natters
Phone: +43 512 54611114 -- schlifkow...@intales.com