On Tue, Jun 01, 2021 at 05:59:10PM +0200, Kevin Wolf wrote: > Am 01.06.2021 um 07:57 hat Sergio Lopez geschrieben: > > Allow block backends to poll their devices/users to check if they have > > been quiesced when entering a drained section. > > > > This will be used in the next patch to wait for the NBD server to be > > completely quiesced. > > > > Suggested-by: Kevin Wolf <[email protected]> > > Signed-off-by: Sergio Lopez <[email protected]> > > --- > > block/block-backend.c | 7 ++++++- > > include/sysemu/block-backend.h | 4 ++++ > > 2 files changed, 10 insertions(+), 1 deletion(-) > > > > diff --git a/block/block-backend.c b/block/block-backend.c > > index de5496af66..163ca05b97 100644 > > --- a/block/block-backend.c > > +++ b/block/block-backend.c > > @@ -2393,8 +2393,13 @@ static void blk_root_drained_begin(BdrvChild *child) > > static bool blk_root_drained_poll(BdrvChild *child) > > { > > BlockBackend *blk = child->opaque; > > + int ret = 0; > > It's really a bool.
I'll fix this in v2.
Thanks,
Sergio.
> > assert(blk->quiesce_counter);
> > - return !!blk->in_flight;
> > +
> > + if (blk->dev_ops && blk->dev_ops->drained_poll) {
> > + ret = blk->dev_ops->drained_poll(blk->dev_opaque);
> > + }
> > + return ret || !!blk->in_flight;
> > }
>
> Doesn't make a difference for correctness, of course, so whether you
> change it or not:
>
> Reviewed-by: Kevin Wolf <[email protected]>
>
signature.asc
Description: PGP signature