Hi Zhenzhong,

On 10/24/25 10:43 AM, Zhenzhong Duan wrote:
> RID-PASID Support(RPS) is not set in vIOMMU ECAP register, the supporting
> code is there but never takes effect.
>
> Meanwhile, according to VTD spec section 3.4.3:
> "Implementations not supporting RID_PASID capability (ECAP_REG.RPS is 0b),
> use a PASID value of 0 to perform address translation for requests without
> PASID."
>
> We should delete the supporting code which fetches RID_PASID field from
> scalable context entry and use 0 as RID_PASID directly, because RID_PASID
> field is ignored if no RPS support according to spec.
>
> This simplifies the code and doesn't bring any penalty.
>
> Suggested-by: Yi Liu <[email protected]>
> Signed-off-by: Zhenzhong Duan <[email protected]>
> ---
>  hw/i386/intel_iommu_internal.h |  1 -
>  hw/i386/intel_iommu.c          | 82 +++++++++++-----------------------
>  2 files changed, 27 insertions(+), 56 deletions(-)
>
> diff --git a/hw/i386/intel_iommu_internal.h b/hw/i386/intel_iommu_internal.h
> index 75bafdf0cd..bf8fb2aa80 100644
> --- a/hw/i386/intel_iommu_internal.h
> +++ b/hw/i386/intel_iommu_internal.h
> @@ -609,7 +609,6 @@ typedef struct VTDRootEntry VTDRootEntry;
>  #define VTD_CTX_ENTRY_LEGACY_SIZE     16
>  #define VTD_CTX_ENTRY_SCALABLE_SIZE   32
>  
> -#define VTD_SM_CONTEXT_ENTRY_RID2PASID_MASK 0xfffff
>  #define VTD_SM_CONTEXT_ENTRY_RSVD_VAL0(aw)  (0x1e0ULL | ~VTD_HAW_MASK(aw))
>  #define VTD_SM_CONTEXT_ENTRY_RSVD_VAL1      0xffffffffffe00000ULL
>  #define VTD_SM_CONTEXT_ENTRY_PRE            0x10ULL
> diff --git a/hw/i386/intel_iommu.c b/hw/i386/intel_iommu.c
> index 70746e3080..06065d16b6 100644
> --- a/hw/i386/intel_iommu.c
> +++ b/hw/i386/intel_iommu.c
> @@ -42,8 +42,7 @@
>  #include "trace.h"
>  
>  /* context entry operations */
> -#define VTD_CE_GET_RID2PASID(ce) \
> -    ((ce)->val[1] & VTD_SM_CONTEXT_ENTRY_RID2PASID_MASK)
> +#define PASID_0    0
>  #define VTD_CE_GET_PASID_DIR_TABLE(ce) \
>      ((ce)->val[0] & VTD_PASID_DIR_BASE_ADDR_MASK)
>  #define VTD_CE_GET_PRE(ce) \
> @@ -963,7 +962,7 @@ static int vtd_ce_get_pasid_entry(IntelIOMMUState *s, 
> VTDContextEntry *ce,
>      int ret = 0;
while you are at it, get rid of ret and simply return
vtd_get_pe_from_pasid_table()?
>  
>      if (pasid == PCI_NO_PASID) {
> -        pasid = VTD_CE_GET_RID2PASID(ce);
> +        pasid = PASID_0;
>      }
>      pasid_dir_base = VTD_CE_GET_PASID_DIR_TABLE(ce);
>      ret = vtd_get_pe_from_pasid_table(s, pasid_dir_base, pasid, pe);
> @@ -982,7 +981,7 @@ static int vtd_ce_get_pasid_fpd(IntelIOMMUState *s,
>      VTDPASIDEntry pe;
>  
>      if (pasid == PCI_NO_PASID) {
> -        pasid = VTD_CE_GET_RID2PASID(ce);
> +        pasid = PASID_0;
>      }
>      pasid_dir_base = VTD_CE_GET_PASID_DIR_TABLE(ce);
>  
> @@ -1522,17 +1521,15 @@ static inline int 
> vtd_context_entry_rsvd_bits_check(IntelIOMMUState *s,
>      return 0;
>  }
>  
> -static int vtd_ce_rid2pasid_check(IntelIOMMUState *s,
> -                                  VTDContextEntry *ce)
> +static int vtd_ce_pasid_0_check(IntelIOMMUState *s, VTDContextEntry *ce)
>  {
>      VTDPASIDEntry pe;
>  
>      /*
>       * Make sure in Scalable Mode, a present context entry
> -     * has valid rid2pasid setting, which includes valid
> -     * rid2pasid field and corresponding pasid entry setting
> +     * has valid pasid entry setting at PASID_0.
>       */
> -    return vtd_ce_get_pasid_entry(s, ce, &pe, PCI_NO_PASID);
> +    return vtd_ce_get_pasid_entry(s, ce, &pe, PASID_0);
>  }
>  
>  /* Map a device to its corresponding domain (context-entry) */
> @@ -1593,12 +1590,11 @@ static int vtd_dev_to_context_entry(IntelIOMMUState 
> *s, uint8_t bus_num,
>          }
>      } else {
>          /*
> -         * Check if the programming of context-entry.rid2pasid
> -         * and corresponding pasid setting is valid, and thus
> -         * avoids to check pasid entry fetching result in future
> -         * helper function calling.
> +         * Check if the programming of pasid setting of PASID_0
> +         * is valid, and thus avoids to check pasid entry fetching
> +         * result in future helper function calling.
>           */
> -        ret_fr = vtd_ce_rid2pasid_check(s, ce);
> +        ret_fr = vtd_ce_pasid_0_check(s, ce);
I guess you should be able to return vtd_ce_pasid_0_check(s, ce)
directly too.
>          if (ret_fr) {
>              return ret_fr;
>          }
> @@ -2110,7 +2106,6 @@ static bool vtd_do_iommu_translate(VTDAddressSpace 
> *vtd_as, PCIBus *bus,
>      bool reads = true;
>      bool writes = true;
>      uint8_t access_flags, pgtt;
> -    bool rid2pasid = (pasid == PCI_NO_PASID) && s->root_scalable;
>      VTDIOTLBEntry *iotlb_entry;
>      uint64_t xlat, size;
>  
> @@ -2122,21 +2117,23 @@ static bool vtd_do_iommu_translate(VTDAddressSpace 
> *vtd_as, PCIBus *bus,
>  
>      vtd_iommu_lock(s);
>  
> -    cc_entry = &vtd_as->context_cache_entry;
any reason why cc_entry setting was moved? Seems a spurious change.
> +    if (pasid == PCI_NO_PASID && s->root_scalable) {
> +        pasid = PASID_0;
> +    }
>  
> -    /* Try to fetch pte from IOTLB, we don't need RID2PASID logic */
> -    if (!rid2pasid) {
> -        iotlb_entry = vtd_lookup_iotlb(s, source_id, pasid, addr);
> -        if (iotlb_entry) {
> -            trace_vtd_iotlb_page_hit(source_id, addr, iotlb_entry->pte,
> -                                     iotlb_entry->domain_id);
> -            pte = iotlb_entry->pte;
> -            access_flags = iotlb_entry->access_flags;
> -            page_mask = iotlb_entry->mask;
> -            goto out;
> -        }
> +    /* Try to fetch pte from IOTLB */
> +    iotlb_entry = vtd_lookup_iotlb(s, source_id, pasid, addr);
> +    if (iotlb_entry) {
> +        trace_vtd_iotlb_page_hit(source_id, addr, iotlb_entry->pte,
> +                                 iotlb_entry->domain_id);
> +        pte = iotlb_entry->pte;
> +        access_flags = iotlb_entry->access_flags;
> +        page_mask = iotlb_entry->mask;
> +        goto out;
>      }
>  
> +    cc_entry = &vtd_as->context_cache_entry;
> +
>      /* Try to fetch context-entry from cache first */
>      if (cc_entry->context_cache_gen == s->context_cache_gen) {
>          trace_vtd_iotlb_cc_hit(bus_num, devfn, cc_entry->context_entry.hi,
> @@ -2173,10 +2170,6 @@ static bool vtd_do_iommu_translate(VTDAddressSpace 
> *vtd_as, PCIBus *bus,
>          cc_entry->context_cache_gen = s->context_cache_gen;
>      }
>  
> -    if (rid2pasid) {
> -        pasid = VTD_CE_GET_RID2PASID(&ce);
> -    }
> -
>      /*
>       * We don't need to translate for pass-through context entries.
>       * Also, let's ignore IOTLB caching as well for PT devices.
> @@ -2202,19 +2195,6 @@ static bool vtd_do_iommu_translate(VTDAddressSpace 
> *vtd_as, PCIBus *bus,
>          return true;
>      }
>  
> -    /* Try to fetch pte from IOTLB for RID2PASID slow path */
> -    if (rid2pasid) {
> -        iotlb_entry = vtd_lookup_iotlb(s, source_id, pasid, addr);
> -        if (iotlb_entry) {
> -            trace_vtd_iotlb_page_hit(source_id, addr, iotlb_entry->pte,
> -                                     iotlb_entry->domain_id);
> -            pte = iotlb_entry->pte;
> -            access_flags = iotlb_entry->access_flags;
> -            page_mask = iotlb_entry->mask;
> -            goto out;
> -        }
> -    }
> -
>      if (s->flts && s->root_scalable) {
>          ret_fr = vtd_iova_to_flpte(s, &ce, addr, is_write, &pte, &level,
>                                     &reads, &writes, s->aw_bits, pasid);
> @@ -2477,20 +2457,14 @@ static void 
> vtd_iotlb_page_invalidate_notify(IntelIOMMUState *s,
>          ret = vtd_dev_to_context_entry(s, pci_bus_num(vtd_as->bus),
>                                         vtd_as->devfn, &ce);
>          if (!ret && domain_id == vtd_get_domain_id(s, &ce, vtd_as->pasid)) {
> -            uint32_t rid2pasid = PCI_NO_PASID;
> -
> -            if (s->root_scalable) {
> -                rid2pasid = VTD_CE_GET_RID2PASID(&ce);
> -            }
> -
>              /*
>               * In legacy mode, vtd_as->pasid == pasid is always true.
>               * In scalable mode, for vtd address space backing a PCI
>               * device without pasid, needs to compare pasid with
> -             * rid2pasid of this device.
> +             * PASID_0 of this device.
>               */
>              if (!(vtd_as->pasid == pasid ||
> -                  (vtd_as->pasid == PCI_NO_PASID && pasid == rid2pasid))) {
> +                  (vtd_as->pasid == PCI_NO_PASID && pasid == PASID_0))) {
don't you need to check you are in s->root_scalable mode too?

Thanks

Eric
>                  continue;
>              }
>  
> @@ -2995,9 +2969,7 @@ static void vtd_piotlb_pasid_invalidate(IntelIOMMUState 
> *s,
>          if (!vtd_dev_to_context_entry(s, pci_bus_num(vtd_as->bus),
>                                        vtd_as->devfn, &ce) &&
>              domain_id == vtd_get_domain_id(s, &ce, vtd_as->pasid)) {
> -            uint32_t rid2pasid = VTD_CE_GET_RID2PASID(&ce);
> -
> -            if ((vtd_as->pasid != PCI_NO_PASID || pasid != rid2pasid) &&
> +            if ((vtd_as->pasid != PCI_NO_PASID || pasid != PASID_0) &&
>                  vtd_as->pasid != pasid) {
>                  continue;
>              }


Reply via email to