I will create a patch for ATAPI for this.

On Mon, Jul 30, 2012 at 6:20 PM, Kevin Wolf <kw...@redhat.com> wrote:
> Am 28.07.2012 03:14, schrieb Ronnie Sahlberg:
>> The START STOP UNIT command will only eject/load media if
>> power condition is zero.
>>
>> If power condition is !0 then LOEJ and START will be ignored.
>>
>> From MMC (sbc contains similar wordings too)
>>   The Power Conditions field requests the block device to be placed
>>   in the power condition defined in
>>   Table 558. If this field has a value other than 0h then the Start
>>   and LoEj bits shall be ignored.
>>
>> Signed-off-by: Ronnie Sahlberg <ronniesahlb...@gmail.com>
>
> Does ATAPI need the same?
>
> Kevin