Public bug reported:

git commit 27c94566379069fb8930bb1433dcffbf7df3203d

The global variable system_clock_scale used in hw/timer/armv7m_systick.c
is never set on the netduinoplus2 platform, it stays initialized as
zero. Using the timer with the clock source as cpu clock leads to an
infinit loop because systick_timer->tick always stays the same.

To reproduce use to CMSIS function SysTick_Config(uint32_t ticks) to
setup the timer.

** Affects: qemu
     Importance: Undecided
         Status: New


** Tags: arm netduinoplus2 systick timer

-- 
You received this bug notification because you are a member of qemu-
devel-ml, which is subscribed to QEMU.
https://bugs.launchpad.net/bugs/1876187

Title:
  qemu-system-arm freezes when using SystickTimer on netduinoplus2

Status in QEMU:
  New

Bug description:
  git commit 27c94566379069fb8930bb1433dcffbf7df3203d

  The global variable system_clock_scale used in
  hw/timer/armv7m_systick.c is never set on the netduinoplus2 platform,
  it stays initialized as zero. Using the timer with the clock source as
  cpu clock leads to an infinit loop because systick_timer->tick always
  stays the same.

  To reproduce use to CMSIS function SysTick_Config(uint32_t ticks) to
  setup the timer.

To manage notifications about this bug go to:
https://bugs.launchpad.net/qemu/+bug/1876187/+subscriptions