​Dear Peter, I am working on Windows machine. Then, I connect the serial port, i.e. UART1, to a virtual COM port on the host. Sending the data from the guest to host works successfully; however, when I send the data from the host to the guest, the guest does not receive anything. I checked it and I find that the interrupt is not raises in the guest although it is enabled. My it is due to a bug in Qemu? or something else that I am missing...? Best, Mahmoud Mahmoud Shirazi, PhD Assistant Professor, Department of Computer Science and Information Technology, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran Tel: +98-24-33153395 http://iasbs.ac.ir/~m.shirazi
On Mon, 05/10/2021 01:24 AM, Peter Maydell <[email protected]> wrote: > On Sun, 9 May 2021 at 17:15, Mahmoud Shirazi " target="_blank"><[email protected]> wrote: > > I checked many machines (boards) in Qemu. Al all of them, all UARTs are as > > gpio-out. Does it means that the connection between the guest and host is > > in one direction (from guest to host)? > > If yes, I there is a way to have a bidirectional connection between the > > guest and host over UART? > > No, UARTs are all bidirectional. You can connect a simulated > UART up to any of QEMU's "chardev" backends (eg to a TCP port, > to the terminal, to a unix pipe), depending on what your needs > are for the host end of the connection. Check the documentation > for details. > > thanks > -- PMM >