On Sun, Jan 15, 2017 at 10:17 PM, Fabien Rouach <[email protected]> wrote: > version 3.0.9 give me initialisation failed when i add disk >
version 3.0.10 fixes the initialization failure. It can be downloaded from http://www.quadstor.com/vtl-extended-edition-downloads.html . Please try with this. > I tried instaling back v3.0.3.6 (that waorks great on my primary server) > with deleting the Db and I still have same issue > difference between servers are : > s1 : DL360 g6 with dual port HBA - OS on RAID 1 disk > s2 : Dl380 g8 with single port HBQ - OS on SD card > Both installed with centos 7 > > I tried stooping the first one to avoid any possible conflict, no change > > Could it be something hardware / OS related? The issues seems to be hardware independent. One thing you could check is if the serial numbers reported by the VTL devices have any sort of conflict. Which tape libraries are being emulated here ? Did you try the hot-swappable device wizard ? > Could the 3.0.8 first installed have done change in OS so I should try > reinstalling OS from scratch? No, that isn't required. Also no changes are done to the VTL system that can change the OS in anyway. > Le jeudi 12 janvier 2017 03:14:03 UTC-8, quadstor a écrit : >> >> Please try 3.0.9 available >> http://www.quadstor.com/vtl-extended-edition-downloads.html >> >> We weren't able to reproduce the issue at our end. Lets see if the new >> release resolves this before we look for additional information. >> >> On Tue, Jan 10, 2017 at 12:56 AM, QUADStor VTL Support >> <[email protected]> wrote: >> > Seems like a regression. There was a change to the element status data >> > returned by the medium changer, its possible that is causing the >> > issue. We will check at our end and get back. >> > >> > On Tue, Jan 10, 2017 at 12:37 AM, Fabien Rouach <[email protected]> >> > wrote: >> >> Hi, >> >> I've a quadstor VTL running v3.0.3.6 used by backup exec 2015, >> >> everything is >> >> fine >> >> I've installed a new one in v3.0.8 used by same backup exec 2015 server >> >> On this one, for every tape library i create, backup exec see a library >> >> with >> >> no drive and the drives separated as independent ones >> >> Never had this trouble with my first test server, any idea what can >> >> cause >> >> that? >> >> >> >> -- >> >> You received this message because you are subscribed to the Google >> >> Groups >> >> "QUADStor VTL" group. >> >> To unsubscribe from this group and stop receiving emails from it, send >> >> an >> >> email to [email protected]. >> >> For more options, visit https://groups.google.com/d/optout. > > -- > You received this message because you are subscribed to the Google Groups > "QUADStor VTL" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > For more options, visit https://groups.google.com/d/optout. -- You received this message because you are subscribed to the Google Groups "QUADStor VTL" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/d/optout.