"Edrusb" <[EMAIL PROTECTED]> wrote in message
news:[EMAIL PROTECTED]
> Detecting when an old interface has "disappeared" should be possible
> looking at the errno global variable when sendto() system call returns
> an error (errno = EINVAL). And I guess, like Bind does, a periodic
> interface scanning plus an "on event" scanning (when sendto() returns an
> error) should be "large" enough to address this problem?
>
> Regards,
> Denis.

Checking errno might be one way to detect when an interface has disappeared.
Assuming that you already have code to read up the list of interfaces on a
server, another simple approach is to run that code again and then compare
the current interface list to what NTP was using previously.