Thanks. In this application, a few thousand dollars is not going to be an issue. Having the correct time is critical and that is why I'm hoping that managment will go for it. I believe the two sources we have now are from GPS.
As to why the two references that we have seem to be different at times, I believe this is most likely due to our third party software or possibly the fact that we have "enable pll" in our NTP configuration file. From what I've been told by a co-worker, NTP can not read time off of a serial line with AIX version 3.4 and that we would need to upgrade to version 4 or 5. This is why we have a third party application reading time off of the serial line and then disciplining the local clock on the NTP servers instead of having NTP do all of this for us. If anyone knows this to be false, please let me know. _______________________________________________ questions mailing list [email protected] https://lists.ntp.isc.org/mailman/listinfo/questions