Steve, I tried few samples and one of which is 2 minutes without -x.
The other samples are 3,5 and 10 minutes with ntpd -x. I see the time changed in one shot for all test. Thanks, Sasi. On 27 Jul 2006 02:47:04 GMT, Steve Kostecke <[EMAIL PROTECTED]> wrote:
On 2006-07-27, Sasikumar Jayaraman <[EMAIL PROTECTED]> wrote: > The default option is that if the offset is less than 128 seconds, it > should slew the clock. The default step threshold is 128 MILLI-seconds. If the offset is below 128 milliseconds ntpd will slew the clock. If the offset is above 128 milliseconds ntpd will step the clock. > I tried changing the timing difference as 2 minutes. But I > could see clock is changed in one shot to clock source. 2 minutes is considerably larger than 128 milliseconds. -- Steve Kostecke <[EMAIL PROTECTED]> NTP Public Services Project - http://ntp.isc.org/ _______________________________________________ questions mailing list [email protected] https://lists.ntp.isc.org/mailman/listinfo/questions