>Another problem with PPS, specifically in the ATOM drivers is that the
>driver provides no information about whether or not it is using the PPS
>signal.

The ATOM driver can't use anything else so all you can get is
1 bit for working or not.  Isn't the reach bit mask good enough
for that?

Actually, there is a little more information.  It checks each second,
collects a batch of samples, and processes the batch when the poll
routine is called.

It would be slightly better to log a line in clockstats with
a count of the batch size and/or maybe some quality indications.
But that only matters if your setup is marginal.  For anything
simple/clean, it should be all or none.  The reach bitmask will
tell you if somebody has tripped over a cable.

-- 
These are my opinions, not necessarily my employer's.  I hate spam.