Hi there
David Lord wrote: > I saw it as CTS on brown and RI on Orange Correct. > All refclocks docs I've checked, by no means all, expect serial > data on RxD. Rewiring the plug might help; Brown and Orange probably have opposite polarity; +-+ +-+ + 12 V | | | | ---+ +-------+ +--- - 12 V ---+ +-------+ +--- + 12 V | | | | +-+ +-+ - 12 V > < 0.1 or 0.2 seconds <--------> 1 or 2 seconds So the thing to do is to connect the positive going pulse to RXD (2). This will probably work with the following NTPD setting; server 127.127.8.0 mode 5 fudge 127.127.8.0 time1 0.220 refid DCF77 After a few minutes 'ntpq -p' should yield something like; remote refid st t when poll reach delay offset jitter ===================================================================== +GENERIC(0) .DCF7. 0 l 61 64 377 0.000 0.151 0.002 Regards Rob -- Nowadays people know the price of everything, and the value of nothing Oscar Wilde _______________________________________________ questions mailing list questions@lists.ntp.org https://lists.ntp.org/mailman/listinfo/questions