In article <4be025aa.4050...@signaturealpha.com>,
 Marc Leclerc <marc-lecl...@signaturealpha.com> writes:

>I am trying to have NTP use the trimble resolution SMT gps module, I
>have tried other trimble clock driver without success so I assume that
>one specific to the module has to be used. Unfortunately there does not
>seems to be any way to search the mailing list to see if this was
>discuss before. I would appreciate if anyone with information could get
>back to me.

>I am trying to make this work on an embedded linux platform, I already
>have the linuxpps driver installed and have the /dev/pps0 node
>available. the module is wired to /dev/ttyS1. Using the clock driver for
>the palisade lead to wrong answer format messages.

The Palisade driver supports several different variations of
Trimble products.  Which one(s) did you try?

The data sheet says it speaks TISP and NMEA.  I don't know which
one is the default.  You might try running some helper code 
before starting ntpd to switch it to NMEA mode, and then telling
ntpd that it's a NMEA device.

-- 