David,
With due respect, your comment has nothing to do with the issue. Allan
deviation is between a quartz crystal oscillator, timer interrupt,
interpolation mechanism and a kerel syscall to read. the clock. It has
nothing whatsoever to do with virtual machines.
Dave
David Woolley wrote:
David L. Mills wrote:
Bill,
Running a precision time server on a busy public machine with a
widely varying load is not a good idea and I have no interest in
that. Running
As indicated by the sort of questions the group is getting recently,
it is becoming the norm to run time servers on virtual machines,
because that is how businesses now run all their servers. The whole
point of virtual machines is that the host is busy and running a
varied load!
_______________________________________________
questions mailing list
[email protected]
http://lists.ntp.org/listinfo/questions
_______________________________________________
questions mailing list
[email protected]
http://lists.ntp.org/listinfo/questions