Steve,

The combine algorithm operates on the survivors of the cluster algorithm, as described on the "How NTP Works" page. The number of survivors can be set using the minclock option. I'm not sure why you want to do this, but the option is there.

Dave

Steve Kostecke wrote:

Is it possible to control the number of time sources included by the
combine algorithm?


_______________________________________________
questions mailing list
[email protected]
http://lists.ntp.org/listinfo/questions