I've noticed that when polling at lower intervals, and PLL is in use, that the frequency tends to change as expected to steer the offset towards zero. When polling intervals increase, and FLL is in use, the frequency tends to follow the offset and not steer the offset towards zero. Why does FLL behave like this? I am using a Windows XP operating system.
_______________________________________________ questions mailing list [email protected] http://lists.ntp.org/listinfo/questions