On Sun, Feb 12, 2012 at 17:36, unruh <[email protected]> wrote: > Uh, that is what ntp tries to do, and is why it shifts up its poll > interval as time goes along ( and since it throws away 80% of > measurments, the effective poll interval is about 8 times as long as the > actual poll interval).
s/effective poll interval/time constant/ That up to 8 x poll time constant is accounted for in the design. There is no bug here. In fact, while you harp endlessly on this point, it's due to the IMHO brilliant minimum delay clock filter which very effectively sifts signal out of noise. ntpd is not going to rip out the clock filter so it can whip around tracking noise as quickly as possible. Please find somewhere else to relieve your bowels. Cheers, Dave Hart _______________________________________________ questions mailing list [email protected] http://lists.ntp.org/listinfo/questions