I discovered that the regulated B+ is running about 175v instead of 180v in my 
R390.  I found R625 had drifted from 1k to 1.2k and, since I think that was 
originally a 1%, I replaced it.  I now get very close to 3.7k at the cathode of 
V609; however, that didn't change the regulated voltage.

I have five 5651s and except for one of them, virtually any two will produce 
175v.  If that fifth tube is in place, I get about 185v.  According to my 
Hickok 752A, the fifth one appears to have a different current draw at its 
regulating voltage and that might account for the difference.

I have a spare 6082 that I've tried swapping in either socket with no 
differences there either.

Running at 115VAC input and getting close to 300v unregulated input to the 
regulator.

It leaves me curious as to how close to 180v is within specification.  I've 
searched the manuals and I can't seem to find a tolerance for that.  Anyone 
know?

Thanks,
Barry - N4BUQ