After rebuilding FL101, replacing CR801, and installing dropping resistors for 
the Antenna Relay and Break-in Relay, I powered up the R390 only to find that 
not only is the B+ 5 volts low (different thread), the Carrier Meter would not 
drop below about 2/3 scale.  I could monitor the AGC voltage with an HP410C and 
verify it was working; however, after checking the pertinent tubes and their 
voltages and resistances I still could not determine why the meter was reading 
so high.  As I recall, before doing work on it, it seemed to be working 
correctly and was thinking I had fouled something up in the process of the work 
I'd done and since I hadn't touched the CARRIER LEVEL ADJ pot, I should leave 
it alone.

I finally decided that all things must to be pointing to the CARRIER LEVEL ADJ 
pot.  Sure enough, it appears to have developed some high resistance at the 
wiper and exercising it allowed me to set the meter zero point as it should be. 
 For whatever reason, I just couldn't convince myself to make that adjustment 
until I finally did.  Lots of wasted time when I should've gone with my 
instinct.  Lesson learned I suppose.