Given that, I should be seeing very close to 7mV (1000 ohms(2.7^2 mA)) across 
R625 and 85V across each VR tube, correct?

Thanks,
Barry - N4BUQ

----- Original Message -----
> From: "Jacques Fortin" <[email protected]>

> In the R-390 PS, the 5651s should run at 2.7mA and have 85 volts across each
> of them.
> The only valid way to test VR tubes is to test those using a DC supply,
> monitoring both the current thru and the voltage across.

> 
> 73, Jacques, VE2JFE in Montreal
______________________________________________________________
R-390 mailing list
Home: http://mailman.qth.net/mailman/listinfo/r-390
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html