Jim, this is most probably due to current leakage of the line filtering capacitors inside the R-390A AC filter. Long-term solution is to change the line filter to a modern one or re-built the old one. Not connecting the safety GND wire is an UNSAFE solution. The only other "simple" way I can think about is to use an isolation transformer (117V to 117V) to prevent current(s) passing in the GND connection of the GFI.
73, Jacques, VE2JFE in Montreal ______________________________________________________________ R-390 mailing list Home: http://mailman.qth.net/mailman/listinfo/r-390 Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html