Jim, this is most probably due to current leakage of the line filtering
capacitors inside the R-390A AC filter.
Long-term solution is to change the line filter to a modern one or re-built
the old one.
Not connecting the safety GND wire is an UNSAFE solution.
The only other "simple" way I can think about is to use an isolation
transformer (117V to 117V) to prevent current(s) passing in the GND
connection of the GFI.

73, Jacques, VE2JFE in Montreal

______________________________________________________________
R-390 mailing list
Home: http://mailman.qth.net/mailman/listinfo/r-390
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to