Ok Jordan, let us know what you found. If ever you doubt about the T207, I still have some spares...
73, Jacques, VE2JFE in Montreal -----Message d'origine----- De : [email protected] <[email protected]> De la part de Jordan Arndt Envoyé : 30 mars 2024 17:37 À : Jacques Fortin <[email protected]>; 'Collins R-390 HF Receiver List' <[email protected]> Objet : Re: [R-390] Tracking down low sensitivity 0 to 8 mhz problem Jacques and the group... I found the expected RF levels In Larry's R-390A oscillator output paper... agn...73... ----- Original Message ----- From: "Jacques Fortin" <[email protected]> To: "'Jordan Arndt'" <[email protected]>; "'Collins R-390 HF Receiver List'" <[email protected]> Sent: Saturday, March 30, 2024 2:19 PM Subject: RE: [R-390] Tracking down low sensitivity 0 to 8 mhz problem Hello Jordan, Some questions: 1_ What is the value fitted for R210 ?? 56K or 220K ?? Have to be a 56K for proper 17MHz output to V202. 2_ Did you replaced C327 ? That cap was flagged as failing in some R-390A. Just put a new SM there, re-peak T207 and retry. 3_ What is the pp voltage measured with J221 directly routed to a 'scope input (with T207 peaked) ?? 73, Jacques, VE2JFE in Montreal -----Message d'origine----- De : [email protected] <[email protected]> De la part de Jordan Arndt Envoyé : 30 mars 2024 14:24 À : Collins R-390 HF Receiver List <[email protected]> Objet : [R-390] Tracking down low sensitivity 0 to 8 mhz problem After a long break from working on 390As, I'm back into a 390A I bought at least 25 years ago. It's the most mongrel 390A I've ever seen, with a modules and assemblies from S-W, Teledyne, Capehart in an early single fuse chassis of unknown mfgr. The front panel is a re-paint and re-letter and the ID tag is a generic after-market type. The RF deck front plate and gear assembly is Teledyne with the deck chassis being a S-W and with a Capehart xtal oscillator module refurbed at Tobyhanna(sp?). I've gotten a good deal of the required rejuvenation work done, but I found an issue where the 1st xtal osc. voltage is rather low when measured as rectified at E-209. I cannot get more than 2v DC measured at E-209, while T207 peaks smoothly. What I've done so far regarding this problem: Replaced the 17Mc xtal, and then the entire oven ass'y including xtals from a working radio to no avail. I then swapped out the 6AK5 osc tube with several good 6AK5/5654 tubes, then did the same with the 6C4 1st mixer tube. Again, all to no effect. Since it has been 25+ years since I originally worked on this radio, I suspected component problems in the RF deck, so I pulled the deck. I pulled C275 and C268 as the originals had been replaced with disk ceramics (what I had on-hand at the time) but both test just fine at 99 and 105pF respectively. I'll replace them with S.M. caps. I then checked every resistor in the RF deck and aside from R203, which had drifted up to 90K from 82K, they all are within spec and show no signs of overheating. Aside from checking feedback caps C324 and C325 to see if one or both have issues, is there anything else I should look at...? Any suggestions or advice would be much appreciated...! 73...Jordan VE6ZT ______________________________________________________________ R-390 mailing list Home: http://mailman.qth.net/mailman/listinfo/r-390 Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html ______________________________________________________________ R-390 mailing list Home: http://mailman.qth.net/mailman/listinfo/r-390 Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html