Just a note here-   Was servicing some later model 67 EAC units and found a 
common issue amongst these with the crystal osc module crystal sockets. This is 
the module with the phenolic framework that gold colored heater cover attaches 
to with 4 of #4 screws.   It seems the crystal socket pins become spread and 
lose contact. I know these units were not messed with much at all so this 
loosening of socket pins occurred on its own through other processes (shock, 
vibration, ?). Have noticed that some of the crystals have a pin bent slightly, 
presumably done by a previous owner to address the problem.   I did not try to 
compress the socket (female) pins to make them tighter. I made sure on the 
loose fitting ones that the slight bend in crystal pin was in correct 
direction; ie not going toward the separation in femal pin. Also I cut a piece 
of insulation about 1/4" thick, very much like found existing one under oven 
top cover, to apply more pressure to rows of crystals to help maintain good 
contact.   I was having trouble with losing crystal oscillations and thought at 
first I needed to look at sync adjustment of switch shaft however that was not 
the case. Byron W5FH
______________________________________________________________
R-390 mailing list
Home: http://mailman.qth.net/mailman/listinfo/r-390
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:R-390@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to