Hi Christian,

Thanks for the reply.

I am using CGP LDAP. Unfortunately, I still haven't located where to adjust the 
timeouts you specified.

But my AuthBy LDAP2 clause has following.

        Host            ldap1_IP ldap2_IP ldap3_IP

        Version         3
        HoldServerConnection
        Timeout         10

I also notice that despite specifying multiple LDAP servers on the Host line 
Radiator does not switch to the alternate servers when the first becomes 
unavailable (physically offline). I had to implement multiple AuthBy LDAP2 
clause and add the clauses to the Handler as a work-around.

Rohan

> On December 16, 2018 at 6:14 AM Christian Kratzer <[email protected]> wrote:
> 
> 
> Hi,
> 
> On Sat, 15 Dec 2018, [email protected] wrote:
> > Hi All,
> >
> >
> > Is this a bug in Radiator (4.12.1)? My ldap servers are all available. And 
> > there's no related logs in ldap for the failure below.
> >
> > Fri Dec 14 11:01:34 2018 953303: DEBUG: Handling with Radius::AuthLDAP2: 
> > CheckADSLBNG
> > Fri Dec 14 11:01:34 2018 963789: DEBUG: Radius::AuthGROUP: CheckADSLBNG 
> > result: IGNORE, User database access error
> > Fri Dec 14 11:01:34 2018 964037: DEBUG: Handling with Radius::AuthLDAP2: 
> > CheckADSLBNG2
> > Fri Dec 14 11:01:34 2018 964269: DEBUG: Radius::AuthGROUP: CheckADSLBNG2 
> > result: IGNORE, User database access error
> 
> this could be related to timeouts in openldap connections.
> 
> Check following parameter for openldap slapd
> 
>         idletimeout <integer>
>                Specify the number of seconds to wait before forcibly closing 
> an
>                idle client  connection.   A  idletimeout  of  0  disables  
> this
>                feature.   The  default  is  0.  You  may  also  want to set 
> the
>                writetimeout option.
> 
> If set openldap will close the socket upon timeout and radiator will only 
> notice on the next request.
> 
> Greetings
> Christian
> 
> -- 
> Christian Kratzer                   CK Software GmbH
> Email:   [email protected]               Wildberger Weg 24/2
> Phone:   +49 7032 893 997 - 0       D-71126 Gaeufelden
> Fax:     +49 7032 893 997 - 9       HRB 245288, Amtsgericht Stuttgart
> Mobile:  +49 171 1947 843           Geschaeftsfuehrer: Christian Kratzer
> Web:     http://www.cksoft.de/
_______________________________________________
radiator mailing list
[email protected]
https://lists.open.com.au/mailman/listinfo/radiator

Reply via email to