This had me and another engineer absolutely confused..

Why is the source port on the CISCO always 1645 and 1646 when
I'm using 1812 and 1813??


radius.cfg has ...
----------------
#
# Authport - where do we listen for AUTHENTICATION (per RFC2138)
#
AuthPort 1812 

#
# Acctport - where do we listen for ACCOUNTING (per RFC2138)
#
AcctPort 1813
-----------------
logfile shows (for CISCO nas)...
-----------------
Fri Mar 26 14:11:41 1999: DEBUG: Packet dump:
*** Received from x.x.x.x port 1646 ....
Code:       Accounting-Request
Identifier: 79
Authentic:  [}<216>i<187><25>/5<132><130><253>'<150><2>Y<160>
Attributes:
        NAS-IP-Address = x.x.x.x
        NAS-Port = 1311440901
        NAS-Port-Type = Async
        User-Name = "notlikely"
        Called-Station-Id = "xxxxxxxxx"
        Acct-Status-Type = Start
        Acct-Authentic = RADIUS
        Service-Type = Framed-User
        Acct-Session-Id = "000142B8"
        Framed-Protocol = PPP
        Acct-Delay-Time = 0
-----------------
logfile shows (for NORTEL nas)...
-----------------
Fri Mar 26 14:13:21 1999: DEBUG: Packet dump:
*** Received from 202.10.4.131 port 1049 ....
Code:       Accounting-Request
Identifier: 167
Authentic:
<215><247>6P6<168><158><184><154><8>(<147><181><189><26><141>
Attributes:
        Acct-Status-Type = Modem-Start
        Acct-Delay-Time = 1
        Acct-Session-Id = "8b080a74"
        NAS-Port = 11
        NAS-Port-Type = Async
        Calling-Station-Id = "296695426"
        Called-Station-Id = "xxxxxxxxx"
        NAS-IP-Address = x.x.x.x

--
Stephen Ollis <[EMAIL PROTECTED]>   Ph: +61 2 9911 1606(BH)  
Team Leader, Server Systems - Network Engineering  +61 2 9911 1555(FAX)
AT&T EasyLink Services, Lvl 8, 15 Orion Rd, Lane Cove, NSW 2066
Australia
"Service to others is the rent you pay for room here on Earth" - M. Ali
 

===
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.

Reply via email to