This had me and another engineer absolutely confused..
Why is the source port on the CISCO always 1645 and 1646 when
I'm using 1812 and 1813??
radius.cfg has ...
----------------
#
# Authport - where do we listen for AUTHENTICATION (per RFC2138)
#
AuthPort 1812
#
# Acctport - where do we listen for ACCOUNTING (per RFC2138)
#
AcctPort 1813
-----------------
logfile shows (for CISCO nas)...
-----------------
Fri Mar 26 14:11:41 1999: DEBUG: Packet dump:
*** Received from x.x.x.x port 1646 ....
Code: Accounting-Request
Identifier: 79
Authentic: [}<216>i<187><25>/5<132><130><253>'<150><2>Y<160>
Attributes:
NAS-IP-Address = x.x.x.x
NAS-Port = 1311440901
NAS-Port-Type = Async
User-Name = "notlikely"
Called-Station-Id = "xxxxxxxxx"
Acct-Status-Type = Start
Acct-Authentic = RADIUS
Service-Type = Framed-User
Acct-Session-Id = "000142B8"
Framed-Protocol = PPP
Acct-Delay-Time = 0
-----------------
logfile shows (for NORTEL nas)...
-----------------
Fri Mar 26 14:13:21 1999: DEBUG: Packet dump:
*** Received from 202.10.4.131 port 1049 ....
Code: Accounting-Request
Identifier: 167
Authentic:
<215><247>6P6<168><158><184><154><8>(<147><181><189><26><141>
Attributes:
Acct-Status-Type = Modem-Start
Acct-Delay-Time = 1
Acct-Session-Id = "8b080a74"
NAS-Port = 11
NAS-Port-Type = Async
Calling-Station-Id = "296695426"
Called-Station-Id = "xxxxxxxxx"
NAS-IP-Address = x.x.x.x
--
Stephen Ollis <[EMAIL PROTECTED]> Ph: +61 2 9911 1606(BH)
Team Leader, Server Systems - Network Engineering +61 2 9911 1555(FAX)
AT&T EasyLink Services, Lvl 8, 15 Orion Rd, Lane Cove, NSW 2066
Australia
"Service to others is the rent you pay for room here on Earth" - M. Ali
===
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.