When attempting a test connection using radpwtst to my MS SQL 7 DB
I get this error:
[root@contender Radiator-2.14]# ./radiusd -config_file platypus.cfg
DBI->connect failed: [iODBC][Driver Manager]Data source name not found and
no default driver specified. Driver could not be loaded (SQL-IM002)
[iODBC][Driver Manager]Data source name not found and no default driver
specified. Driver could not be loaded (SQL-IM002)(DBD: db_login/SQLConnect
err=-1) at Radius/SqlDb.pm line 116
Sat Oct 30 16:21:03 1999: ERR: Could not connect to SQL database with
DBI->connect dbi:ODBC:PLATYPUS2@HINDSIGHT, platuser, fewlfewl:
[iODBC][Driver Manager]Data source name not found and no default driver
specified. Driver could not be loaded (SQL-IM002)
[iODBC][Driver Manager]Data source name not found and no default driver
specified. Driver could not be loaded (SQL-IM002)(DBD: db_login/SQLConnect
err=-1)
Sat Oct 30 16:21:03 1999: ERR: Could not connect to any SQL database.
Request is ignored. Backing off for 600 seconds
My platypus.cfg looks like this:
<Realm DEFAULT>
<AuthBy PLATYPUS>
# Change DBSource, DBUsername, DBAuth for your database
# See the reference manual
DBSource dbi:ODBC:PLATYPUS2@HINDSIGHT
DBUsername platuser
DBAuth password
Does anyone know what is the likely problem here?
Thanks in advance.
Dean Brandt
+-------------------------------------------------+
Cain Internet Services
Melbourne - Adelaide - Sydney - Brisbane - Bendigo
Australia
Ph/Fax: 61-3-93810595
Mobile: 0413247188
www.cain.net.au
+-------------------------------------------------+
===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.