On Thu, 16 Mar 2000, Hugh Irvine wrote:
> Hello Jeremy -
>
> On Thu, 16 Mar 2000, Jeremy C. Reed wrote:
> > Our accounting details files on different servers for the past couple
> > weeks have been logging the same information. We recently upgraded
> > Radiator a couple weeks ago.
> >
> > Our Ascend and Erickson access servers have the IPs for each of our
> > accounting servers. Before, only one or the other recorded the
> > information; now both are recording the exact information. The only thing
> > that is different is the formatted date and time (not the Timestamp
> > value). It appears to be exactly 45 seconds apart -- which is the same as
> > our Ascent TNT's timeout value.
> >
> > Does anyone have any ideas where to look, how to further trouble-shoot
> > this or what settings to use to get the logging only done once?
> >
>
> I think I will need to see the configuration files (no secrets) and a trace 4
> debug from both Radiator servers as well.
I also noticed that the same server also logs accounting information
duplicate times.
For example, I did a:
grep "Acct-Session-Id" detail | sort
and some if the Acct-Session-Id's were listed over five times.
Then I looked in the detail file for these Id's and some were duplicate
accounting information, but also the same Id was used for other
connections (different users). So it is not unique.
Here are the configuration files:
http://www.iwbc.net/~jcr/temp-radiator/radiator.cfg
http://www.iwbc.net/~jcr/temp-radiator/proxies.cfg
(The same configs are on both servers.)
Here is some Trace 4 logging:
http://www.iwbc.net/~jcr/temp-radiator/logfile-ns2
http://www.iwbc.net/~jcr/temp-radiator/logfile-bu-sea
For example, Acct-Session-Ids 278956876 and 278956941
are logged six times each on bu-sea; twice on ns2.
If you'd rather have this info by email or you need further info, please
let me know.
Thanks,
Jeremy C. Reed [EMAIL PROTECTED]
UNIX Admin Fax: 425-290-1751
IWBC ISP Services http://www.iwbc.net
===
Archive at http://www.starport.net/~radiator/
Announcements on [EMAIL PROTECTED]